Installation
4-16
BA9300POS EN 2.3
Types 9330 and 9331
T1
T2
PE
UV
W
M5 X 12
Carry out strain relief using cable binders .
Correct screen connection with screened cables:
Apply motor cable screen to the screening plate using
clamp and M5x12 bolts
ó.
Fix the screen of the thermal contact (see
^
4-28 ) at
the PE stud next to the motor connection with a surface
as large as possible.
Type 9332
T1
T2
PE
U
V
W
M5 X 12
M4 X 12
Carry out strain relief using clamps and M4x12 bolts ì.
An additional strain relief/fixing is possible with cable
binders
.
Correct screen connection with screened cables:
Apply motor cable screen to the screening plate using
clamp and M5x12 bolts
ó.
Fix the screen of the thermal contact (see
^
4-28 ) at
the PE stud next to the motor connection with a surface
as large as possible.
Fig. 4-8 Proposal for the motor connection