Installation
4-27
BA9300POS EN 2.3
Features:
CAN-based with bus protocol according to CANopen (CAL-based Communication Profile
DS301)
Bus extension:
25 m for max. 1 Mbit/s baud rate
–upto1kmwithreducedbaudrate
Very reliable data transmission (Hamming distance = 6)
Signal level according to ISO 11898
Up to 63 bus devices are possible
Access to all Lenze parameters
Master functions are integrated into the controller
Data exchange possible between controllers without participation of a master system
(current ratio control, speed synchronization, etc.)
The following connections of the system bus connection are possible:
Connection to a decentral terminal extension for digital and analog inputs and outputs
Connection to a superimposed control (PLC, position control, operating terminal)
Connection between several controllers
Tip!
Further information can be obtained from the Manual of your controller.
Automation interface (X1)
The automation interface (X1) is used for the connection of different plug-on modules
Operating module
Fieldbus modules
2102 LECOM-A/B/LI
2111 INTERBUS
2112 INTERBUS loop
2131 PROFIBUS-DP and 2133 PROFIBUS-DP
2174 CAN addressing module
2175 DeviceNet / CANopen