Appendix
Code table
14−41
L
EDB82MV752 EN 5.2
Code IMPORTANTPossible settings
No. SelectionLenzeName
C0415
(cont.)
Possible digital signals for C0415
7−68
AIF control word (AIF−CTRL)
Permanently assigned bits of AIF−CTRL:
Bit 3: QSP
Bit 7: CINH
Bit 10: TRIP−SET
Bit 11: TRIP−RESET
40 Bit 0
...
...
55
Bit 15
CAN−IN1.W1 or FIF−IN.W1
60 Bit 0
...
...
75
Bit 15
CAN−IN1.W2 or FIF−IN.W2
80 Bit 0
...
...
95
Bit 15
CAN−IN2.W1
100 Bit 0
...
...
115
Bit 15
CAN−IN2.W2
120 Bit 0
...
...
135
Bit 15
Status application I/O
Only active for operation with application
I/O
140 Torque threshold 1 reached (MSET1=MOUT)
141
Torque threshold 2 reached (MSET2=MOUT)
142
Limitation of process controller output reached
(PCTRL1−LIM)
143 ...
172
Reserved
255
Not assigned (FIXED−FREE)
C0416
Level inversion of
digital outputs
0
0 Level inversion is switched off By entering the sum of the selected values
you can invert several outputs
7−73
1 Relay K1
2 X3/A1
4 X3/A2 only application I/O
8 Relay K2 Relay output K2 only with 8200 vector 15 ...
90 kW