Commissioning
Parameter setting using the keypad
5−3
L EDB82MV752 EN 5.2
5.2.2 Changing and saving parameters
) Note!
l The user menu user is active after mains switching. Change to the menu all to
address all codes.
l In the different parameter sets only parameter values can be changed with the
keypad.
l Digital signals must be used to activate a parameter set for operation
(configuration with C0410)!
l In the function the display shows the parameter set which is just active
during operation.
Step Keys Result Action
1. Connect keypad
xx.xx Hz
Function is activated. The first code in the user menu will be
displayed (C0517/1, Lenze setting: C0050 = output frequency).
2. If necessary change to
the menu "ALL"
Change to function bar 2
3.

4.

all Select menu "ALL" (list of all codes)
5.
Confirm selection and change to function bar 1
6. Select parameter set for
change
Change to function bar 2
7.

8.

1 ... 4 Select parameter set to be changed
9.
Confirm selection and change to function bar 1
10. Inhibit controller

Only necessary if you want to change C0002, C0148, C0174 and/or
C0469
11. Set parameters

12.
 XXXX
Select code
13.
001
For codes without subcodes: Jump automatically to
14.
 XXX
Select subcode
15.
16.
 XXXXX
Set parameters
17.
STOre
Confirm entry if is blinking
Confirm entry if is not blinking; is not active
18. Restart the "loop" at 11. or 6. to set other parameters.