EasyManua.ls Logo

Lenze E82MV152_4B

Lenze E82MV152_4B
270 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
Rated data at 400/500 V mains voltage
3−9
L
EDB82MV752 EN 5.2
3.3.2 Operation with increased rated power
Under the application conditions described here the controller can be operated in continuous
operation with a motor of higher performance. The overload capacity is reduced to 120 %.
Typical applications:
Pumps with quadratic load characteristic
Fan
Operation is only permissible
in the mains voltage ranges mentioned
at a switching frequency of 2 or 4 kHz
with the prescribed fuses and cable cross−sections
Typical motor power
Three−phase asynchronous motor
(4−pole)
P
N
[kW] 0.75 1.1 2.2 3.0
P
N
[hp] 1.0 1.5 3.0 4.0
8200 motec Type E82MV551_4B E82MV751_4B E82MV152_4B E82MV222_4B
Mains voltage U
mains
[V] 3/PE AC 320 V − 0 % ... 440 V + 0 % ; 45 Hz − 0 % ... 65Hz + 0 %
Data for operation on 3/PE AC 400 V 400 V 400 V 400 V
Rated mains current I
mains
[A] 2.2 2.8 4.6 6.6
Rated output current at
switching frequency
2 kHz
I
N24
[A] 2.1 2.9 4.6 6.7
4 kHz
Max. permissible output
current for 60 s at
switching frequency
1)
2 kHz
I
max24
[A] 2.7 3.6 5.8 8.4
4 kHz
Output voltage U
M
[V] 3~ 0 ... U
mains
/ 0 ... 650 Hz
Power loss (operation with I
N8
) P
v
[W] 35 45 70 95
Dimensions L x W x H [mm] 202 x 156 x 151 230 x 176 x 167
Weight m [kg] 2.8 2.8 4.1 4.1
Typical motor power
Three−phase asynchronous motor
(4−pole)
P
N
[kW] 4 5.5 7.5
P
N
[hp] 5.4 7.5 10.2
8200 motec Type E82MV302_4B E82MV402_4B E82MV552_4B
Mains voltage U
mains
[V] 3/PE AC 320 V − 0 % ... 440 V + 0 % ; 45 Hz − 0 % ... 65Hz + 0 %
Data for operation on 3/PE AC 400 V 400 V 400 V
Rated mains current I
mains
[A] 11.4 14.8 20.2
Rated output current at
switching frequency
2 kHz
I
N24
[A] 8.8 11.4 15.6
4 kHz
Max. permissible output
current for 60 s at
switching frequency
1)
2 kHz
I
max24
[A] 11.0 14.2 19.5
4 kHz
Output voltage U
M
[V] 3~ 0 ... U
mains
/ 0 ... 650 Hz
Power loss (operation with I
N8
) P
v
[W] 140 180 230
Dimensions L x W x H [mm] 325 x 211 x 163 (223**)
Weight m [kg] 9.7 9.7 9.7
Bold print = data for operation at a switching frequency of 8 kHz (Lenze setting)
1)
Currents for periodic load change with 1 min overcurrent time with I
max
and 2 min base load time with 75 % I
Nx
** for wall mounting or with a supplementary module (E82ZMV)

Table of Contents

Related product manuals