Installation
Electrical installation
Cable cross−sections and screw−tightening torques
5
l
24
EDS82ZAFIC EN 2.0
5.2.5 Cable cross−sections and screw−tightening torques
E82ZAFIC001function module
Range Values
Electrical connection Terminal strip with screw connection
Possible connections
rigid:
1.5 mm
2
(AWG 16)
flexible:
without wire end ferrule
1.0 mm
2
(AWG 18)
with wire end ferrule, without plastic sleeve
0.5 mm
2
(AWG 20)
with wire end ferrule, with plastic sleeve
0.5 mm
2
(AWG 20)
Tightening torque 0.22 ... 0.25 Nm (1.9 ... 2.2 lb−in)
Bare end 5 mm
Function module E82ZAFIC010 (PT version)
Field Values
Electrical connection 2−pin plug connector with spring connection
Possible connections
rigid:
1.5 mm
2
(AWG 16)
flexible:
without wire end ferrule
1.5 mm
2
(AWG 16)
with wire end ferrule, without plastic sleeve
1.5 mm
2
(AWG 16)
with wire end ferrule, with plastic sleeve
1.5 mm
2
(AWG 16)
Stripping length 9 mm