EasyManua.ls Logo

Lenze E82ZAFIC001 - Communication-relevant Lenze codes

Lenze E82ZAFIC001
71 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Codetabelle
Communication−relevant Lenze codes
10
l
58
EDS82ZAFIC EN 2.0
10.1 Communication−relevant Lenze codes
C1510:
Configuring process input data
Code
C1510
Name
Configuring process input data
Index
0x5A19 (23065)
Subcode Lenze Values Access Data type
1 PIW1 18
see table below rw FIX32
2 PIW2 3
3 PIW3 4
4 PIW 4 5
þ Parameter set transfer
The assignment of the bit status information or actual values of the controller to the max.
4 process input data words (PIW) of the master can be configured freely.
) Note!
For reasons of compatibility, subcodes 5 and 6 can also be read and written
with modules from software version V3.0. However, this has no effect.
Selection Scaling
1 FIF status word 1 (FIF−STAT1) 16 bits
2 FIF status word 2 (FIF−STAT2) 16 bits
3 Output frequency with slip (MCTRL1−NOUT+SLIP) ±24000 º ±480 Hz
4 Output frequency without slip (MCTRL1−NOUT) ±24000 º ±480 Hz
5 Apparent motor current (MCTRL1−IMOT) 2
14
º 100 % rated device current
6 Actual process controller value (PCTRL1−ACT) ±24000 º ±480 Hz
7 Process controller setpoint (PCTRL1−SET) ±24000 º ±480 Hz
8 Process controller output (PCTRL1−OUT) ±24000 º ±480 Hz
9 Device utilisation (MCTRL1−MOUT) ±2
14
º ±100 % rated motor torque
10 DC−bus voltage (MCTRL1−DCVOLT) 16383 º 565 VDC at 400 V mains
16383 º 325 VDC at 230 V mains
11 Ramp function generator input (NSET1−RFG1−IN) ±24000 º ±480 Hz
12 Ramp function generator output (NSET1−NOUT) ±24000 º ±480 Hz
13 FIF−OUT.W1 16 bits or 0 ... 65535
14 FIF−OUT.W2 16 bits or 0 ... 65535
15 FIF−OUT.W3 0 ... 65535
16 FIF−OUT.W4 0 ... 65535
17 DRIVECOM control word (DRIVECOM−CTRL) 16 bits
18 DRIVECOM status word (DRIVECOM−STAT) 16 bits

Table of Contents