8.2 Initialise PCP communication
8.2.1 CRL entries
In order that communication between the host (master) and the function/communication
module can take place, the following entries in the communication relation list (CRL) of the
master have to be set:
Field name Entry
Communication reference 2
Connection type Master/slave acyclic
Connection attribute Defined
Max−PDU Sending−High−Prio 0
Max−PDU Sending−Low−Prio 64
Max−PDU Receiving−High−Prio 0
Max−PDU Receiving−Low−Prio 64
Supported Services Request 0x803000
Supported Services Response 0x000000
Maximum SCC 1
Maximum RCC 1
Maximum SAC 1
Maximum RAC 1
8.2.2 Available PCP services
The PCP services (PCP = Peripherals Communication Protocol) serve to transmit
parameters via the PCP channel.
Lenze controllers support the following PCP services:
ƒ "Initiate": Establishing connection from the master to the controller ( 50)
ƒ "Abort": Aborting connection ( 50)
ƒ "Read": Reading parameters ( 51)
ƒ "Write": Writing parameters ( 51)
ƒ "Get−OD": Reading out the object directory (OD) ( 51)
ƒ "Identify": Identification of the controller ( 52)
ƒ "Status": Reading the status of the controller ( 53)
In the following, only those parameters and their contents are shown which are returned
by the Lenze controllers. All other transfer parameters of the given PCP services can be
obtained from the corresponding descriptions of the master.