Parameter data transfer
Initialise PCP communication
Available PCP services
8
l
52
EDS82ZAFIC EN 2.0
Identify
The "Identify" PCP service provides information on how to identify the controller. The
controller provides the following parameters:
Designation Value Meaning
Name of device
manufacturer
"Lenze" (as visible string) Company name
Device name Visible string with 15
characters
Device name for controller and
function/communication module
Device version Visible string with 15
characters
Software version of the device
Device name
Composition of the visible string:
ƒ Characters 1 ... 5: Name of the controller
4 characters of device name
1 space
ƒ Characters 6 ... 10: Name of the function/communication module
4 characters of device name
1 space
ƒ Characters 11 ... 15: No name
5 space
If no function/communication module is available, the corresponding area is filled with
spaces.
Example:
8200 vector controller with communication module EMF2113IB: "8212 2113 "
Visible string
Device name
Standard device
Device name
Module
Space
8212 2113
16
11 15

Table of Contents