EasyManua.ls Logo

Lenze E82ZAFIC001 - Page 31

Lenze E82ZAFIC001
71 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning
Defining the user data length
6
l
31
EDS82ZAFIC EN 2.0
Settings via code
ƒ DIP switches S2 ... S4 = ON
ƒ Set the number of data words (PCD + PCP) via C1515.
Code
C1515
Name
Process/parameter data specification
Index
0x5A14 (23060)
Subcode Lenze Values Access Data type
0
0, 1, 4, 5
rw FIX32
11 ... 14
21 ... 23
Values Description
0, 1, 4, 5 The configuration resulting from the values corresponding to the set DIP switch
positions becomes active.
11 ... 14 l No PCP
l 11 (1 word PCD) ... 14 (4 words PCD)
21 ... 23 l 1 word PCP
l 21 (1 word PCD) ... 23 (3 words PCD)

Table of Contents

Related product manuals