Loading...
Process data transfer
Lenze device control
Process data signals for 8200 vector / 8200 motec
7
l
39
EDS82ZAFIC EN 2.0
Configuring process input data
The assignment of the bit status information or actual values of the controller to the max.
4 process input data words (PIW) of the master can be configured freely:
ƒ In order to access DRIVECOM−compliant status information, assign the DRIVECOM
status word to a PIW (C1511/x = 18).
ƒ The FIF status word1 is mapped to the DRIVECOM status word.
Configuration of the process input data
Code
C1510
Name
Configuring process input data
Index
0x5A19 (23065)
Subcode Lenze Access Data type
1 PIW1 18 DRIVECOM status word (DRIVECOM−STAT) rw FIX32
2 PIW2 3 Output frequency with slip (MCTRL1−NOUT+SLIP) rw FIX32
3 PIW3 4 Output frequency without slip (MCTRL1−NOUT) rw FIX32
4 PIW4 5 Apparent motor current (MCTRL1−IMOT) rw FIX32
þ Parameter set transfer
I Tip!
For a detailed description of the code, see ^ 58.