Codetabelle
Diagnostics
10
l
64
EDS82ZAFIC EN 2.0
C1522:
Display of all process data words to the standard device
Code
C1522
Name
Display of all process data words to the standard device
Index
0x5A0D (23053)
Subcode Lenze Values Access Data type
1 ... 16
g
0 [1] 65535 r U16
o Parameter set transfer
Display of the process data output words 1 ... 16 that are transferred from the
function/communication module to the standard device:
Subcode Process data word
1 FIF control word 1 (FIF−CTRL1)
2 FIF control word 2 (FIF−CTRL2)
3 Setpoint 1 (NSET1−N1)
4 Setpoint 2 (NSET1−N2)
5 Additional setpoint (PCTRL1−NADD)
6 Actual process controller value (PCTRL1−ACT)
7 Process controller setpoint (PCTRL1−SET1)
8 reserved
9 Torque setpoint or torque limit (MCTRL1−MSET)
10 PWM voltage (MCTRL1−VOLT−ADD)
11 PWM angle (MCTRL1−PHI−ADD)
12 reserved
13 FIF−IN.W1
14 FIF−IN.W2
15 FIF−IN.W3
16 FIF−IN.W4