Appendix
Data transfer
Overview of the implemented objects for the function module
9
l
57
EDS82ZAFVCxxx EN 4.0
Assembly class (04
hex
)
Instance 101 ... 112:
Attribute Service(s) Description Data type Instance / value
3 GET / SET Data Array of BYTE
Instance 101:
1 word (= 2 byte) from master
Instance 102:
2 words (= 4 byte) from master
Instance 103:
3 words (= 6 byte) from master
Instance 104:
4 words (= 8 byte) from master
Instance 105:
5 words (= 10 byte) from master
Instance 106:
6 words (= 12 byte) from master
Instance 107:
7 words (= 14 byte) from master
Instance 108:
8 words (= 16 byte) from master
Instance 109:
9 words (= 18 byte) from master
Instance 110:
10 words (= 20 byte) from master
Instance 111:
11 words (= 22 byte) from master
Instance 112:
12 words (= 24 byte) from master