Commissioning
Configuring the digital inputs and outputs
Change of the terminal assignment
6
124
EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
[C7411] Selection of the signal source for
the digital input signals of the
"Speed" function block
1 SpeedIn−dig 1000 0 (FALSE, not assigned) CW rotation (SPEED−RLQ.Cw)
325
2 SpeedIn−dig 1000 0 (FALSE, not assigned) CCW rotation (SPEED−RLQ.CCw)
3 SpeedIn−dig 1000 0 (FALSE, not assigned) Selection of the fixed speeds
(SPEED−NSET.Jog1) saved in
C0039
326
4 SpeedIn−dig 1000 0 (FALSE, not assigned) Selection of the fixed speeds
(SPEED−NSET.Jog2)saved in
C0039
5 SpeedIn−dig 1000 0 (FALSE, not assigned) Selection of the fixed speeds
(SPEED−NSET.Jog4)saved in
C0039
6 SpeedIn−dig 1000 0 (FALSE, not assigned) Selection of the fixed speeds
(SPEED−NSET.Jog8)saved in
C0039
7 SpeedIn−dig 1000 0 (FALSE, not assigned) Setting of the speed setpoint
integrator to 0 along the
adjusted ramps
(SPEED−NSET.Rfg0)
326
8 SpeedIn−dig 1000 0 (FALSE, not assigned) Inversion of additional speed
setpoint (SPEED−NAddInv)
9 SpeedIn−dig 1000 0 (FALSE, not assigned) Keeping (freezing) the speed
setpoint integrator to the actual
value (SPEED-NSET.RfgStop)
10 SpeedIn−dig 1000 0 (FALSE, not assigned) Activation of the motor holding
brake (SPEED−BRK.SetBrake)
340
11 SpeedIn−dig 1000 0 (FALSE, not assigned) Switching of speed − torque
(SPEED−MCTRL.NMSwt)
332
12 SpeedIn−dig 1000 0 (FALSE, not assigned) Source for the integral−action
component of the speed
controller (SPEED−MCTRL.ILoad)
13 SpeedIn−dig 1000 0 (FALSE, not assigned) Selection of the acceleration and
deceleration times stored in
C0101 and C0103
(SPEED−NSET.TI1)
326
14 SpeedIn−dig 1000 0 (FALSE, not assigned) Selection of the acceleration and
deceleration times stored in
C0101 and C0103
(SPEED−NSET.TI2)
15 SpeedIn−dig 1000 0 (FALSE, not assigned) Selection of the acceleration and
deceleration times stored in
C0101 and C0103
(SPEED−NSET.TI4)
16 SpeedIn−dig 1000 0 (FALSE, not assigned) Selection of the acceleration and
deceleration times stored in
C0101 and C0103
(SPEED−NSET.TI8)
17 SpeedIn−dig 1000 0 (FALSE, not assigned) Setting of quick stop
(SPEED−QSP.Set1)
332
18 SpeedIn−dig 1000 0 (FALSE, not assigned) Setting of quick stop
(SPEED−QSP.Set2)
19 SpeedIn−dig 1000 0 (FALSE, not assigned) Activation of phase controller
(SPEED-MCTRL.PosOn)
20 SpeedIn−dig 1000 0 (FALSE, not assigned) Inversion of additional torque
setpoint (SPEED−MAddInv)