Appendix
Code table
13
380
EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
C0220 NSET Tir add 0.000
Acceleration time for the
additional setpoint
331
0.000 {0.001 s} 999.999 Relating to speed variation
0 rpm ... n
max
(C0022)
C0221 NSET Tif add 0.000
Deceleration time for the
additional setpoint
331
0.000 {0.001 s} 999.999 Relating to speed variation
0 rpm ... n
max
(C0011)
C0241 NSET RFG I = O 1.00
Threshold for message "Setpoint
reached"
On the ramp function generator
for
l speed setpoint (for "speed
control")
l torque setpoint (for "torque
control")
input signal = output signal.
329
352
0.00 {0.01 %} 100.00 100 % = n
max
C0244 BRK M set 0.00
Holding torque of the drive
against the motor holding brake
340
360
102
−199.99 {0.01 %} 199.99 Referring to M
max
(C0057).
During the time set in C0196 the
drive generates the set torque
against the holding brake.
C0250 FCODE 1 Bit 0
Freely selectable digital signal
(1 bit)
309
0 1
C0254 Vp angle CTRL 0.4000
Phase controller gain (V
p
)
337
0.0000 { 0.0001} 3.9999
C0300
Service Codes Only the Lenze service is allowed
to make changes!
...
C0302
C0304
Service Codes Only the Lenze service is allowed
to make changes!
...
C0310