Loading...
Commissioning
Important notes
DANGER!
Incorrect wiring can cause unexpected states during the commissioning phase.
Possible consequences: death, severe injuries or damage to property
Ensure the following before switching on the mains voltage:
Wiring must be complete and correct.
Wiring must be free of short circuits and earth faults.
The motor circuit conguraon (star/delta) must be adapted to the inverter output voltage.
The motor must be connected in-phase (direcon of rotaon).
The "emergency o" funcon of the overall system must operate correctly.
DANGER!
Incorrect sengs during commissioning may cause unexpected and dangerous motor and system
movements.
Possible consequences: death, severe injuries or damage to property
Clear hazardous area.
Observe safety instrucons and safety clearances.