1-phase mains connecon 230/240 V
Rated data
The inverters I51AExxxD do not have an integrated RFI lter in the AC mains supply.
In order to meet the EMC requirements according to EN 61800−3, an external EMC lter according
to IEC EN 60939 must be used.
The user must verify that the conformity with EN 61800−3 is fullled.
The output currents apply to these operang condions:
At a switching frequency of 2 kHz or 4 kHz: Max. ambient temperature 45 °C.
At a switching frequency of 8 kHz or 16 kHz: Max. ambient temperature 40 °C.
Inverter I51AE
125B 125D 137B 137D 155B 155D 175B 175D 211B 211D 215B 215D
Rated power P
rated
kW 0.25 0.37 0.55 0.75 1.1 1.5
Rated power P
rated
hp 0.33 0.5 0.75 1 1.5 2
Mains voltage range 1/PE AC 170 V ... 264 V, 45 Hz ... 65 Hz
Output voltage 3 AC 0 - 230/240 V
Rated mains current
without mains choke A 4 5.7 7.6 10 14.3 16.7
with mains choke A 3.6 4.8 7.1 8.8 11.9 13.9
Apparent output power kVA 0.6 0.9 1.2 1.6 2.2 2.6
Rated output current
2 kHz A - 3.2 4.2 6 7
4 kHz A 1.7 2.4 3.2 4.2 6 7
8 kHz A 1.7 2.4 3.2 4.2 6 7
16 kHz A 1.1 1.6 2.1 2.8 4 4.7
Power loss
2 kHz W - 22 27 36 41
4 kHz W 15 18 23 29 37 43
8 kHz W 15 20 25 33 42 50
16 kHz W 19 24 30 38 51 59
Cyclic mains switching 3 mes per minute
Brake chopper
Max. output current -
Min. brake resistance -
Max. motor cable length
shielded
without EMC category m 50
Category C1 (2 kHz, 4 kHz,
8 kHz)
m -
Category C2 (2 kHz, 4 kHz,
8 kHz)
m 15 - 15 - 20 - 20 - 20 - 20 -
Category C3 (2 kHz, 4 kHz,
8 kHz)
m 15 - 15 - 50 - 50 - 35 - 35 -
Max. motor cable length
unshielded
without EMC category m -
Technical data