Motor connecon
Requirements for the shielded motor cable
Capacitance per unit
length
< 150/300 pF/m C core-core/C core-shield ≤ 4 mm² / AWG 12
< 75/150 pF/m C core-core/C core-shield ≤ 2.5 mm² / AWG 14
Electric strength
Uo/U = 0.6/1.0 kV
U = r.m.s. value from external conductor to external
conductor
Uo = r.m.s. value external conductor to PE
UL U ≥ 600 V
U = r.m.s. value from external conductor to external
conductor
Environmental condions
Energy eciency
High Eciency EN 50598-2 Class IE2
Climate
Storage
EN IEC
60721-3-1:1997
1K3 (-25 ... +60 °C)
Transport
EN IEC
60721-3-2:1997
2K3 (-25 ... +70 °C)
Operaon
EN IEC
60721-3-3:1995
+ A2:1997
3K3 (-10 ... +60 °C)
Operaon at a switching frequency of 2 or 4 kHz: Above
+45°C: reduce rated output current by 2.5 %/°C
Operaon at a switching frequency of 8 or 16 kHz:
Above +40°C: reduce rated output current by 2.5 %/°C
3C3 For chemically acve substances
3S2 For mechanically acve substances
Site altude
0 … 1000 m amsl without current derang
1000 … 4000 m amsl Reduce rated output current by 5 %/1000 m
Polluon
EN 61800-5-1
Degree of polluon 2
UL 61800-5-1
Vibraon resistance
Transport
EN IEC
60721-3-2:1997
2M2 (sine, shock) in original packaging
Operaon
EN 61800-5-1
Amplitude 0.075 mm 10 ... 57 Hz
acceleraon resistant up to 1
g
57 ... 150 Hz
German Lloyd
Amplitude 1 mm 5 ... 13.2 Hz
acceleraon resistant up to
0.7 g
13.2 ... 100 Hz
Electrical supply condions
Power systems
IT
Apply the measures described for IT systems!
IT systems not relevant for UL-approved systems
TN
Voltage to earth: max. 300 V
TT
Technical data
Standards and operang condions
Electrical supply condions