E94AYCEN communication manual (Ethernet)
Technical data
Protective insulation
16 L EDS94AYCEN EN 9.0 - 09/2012
4.2 Protective insulation
Danger!
Dangerous electrical voltage
If Servo Drives 9400 are used on a phase earthed mains with a rated mains
voltage 400 V, protection against accidental contact is not guaranteed
without external measures.
Possible consequences:
Death or severe injuries
Protective measures:
If protection against accidental contact is required for the control terminals
of the drive and for the connections of the plugged-in device modules, ...
a double isolating distance must exist.
the components to be connected must be provided with the second
isolating distance.
Note!
The protective insulation provided in Servo Drives 9400 is implemented in
accordance with EN 61800-5-1.