EDS94AYCEN EN 9.0 - 09/2012 L 43
E94AYCEN communication manual (Ethernet)
Parameter data transfer
Error codes
7.6 Error codes
The error code is located in the User data area P0, byte 1 and byte 2.
Possible error codes
User data area P0
Byte 1 Byte 2 Byte 3 Byte 4
Error code Data type Reserved
Example error code 0x9002
Low byte High byte
0x02 0x90
Note!
The other user data contents correspond to those of an error-free message.
Error code Definition Description
dec hex
33803 0x840B Invalid type Invalid parameter type
33805 0x840D FB not found Function block not found
33812 0x8414 Invalid size Invalid parameter format
33813 0x8415 Not in select list Parameter is not in the selection list
33814 0x8416 Read not allowed Parameter read is not allowed
33815 0x8417 Write not allowed Parameter write is not allowed
33816 0x8418 CINH not set Controller inhibit is not set
33817 0x8419 PLC not stopped The PLC is not in the "Stopped" status
33828 0x8424 Invalid index Invalid parameter index
33829 0x8425 Invalid subindex Invalid parameter subindex
33837 0x842D Access not allowed Parameter access not allowed
33848 0x8438 Invalid length Invalid parameter length
33862 0x8446 Unallowed characters Parameter contains invalid characters
33865 0x8449 No array parameter Parameter is no array parameter
33874 0x8452 Invalid select index Invalid selection index
36866 0x9002 No memory available No more memory available
36867 0x9003 No TID available No transaction ID (TID) available
anymore for identifying the telegram.
TIDs are released again after receiving a
reply with the corresponding TID.
36868 0x9004 Channel init error General error when opening the
communication channel
36869 0x9005 Error if not connected No connection could be established.
36870 0x9006 Error of send function Error when sending a GCI telegram
36871 0x9007 Error of receive function Error when receiving a GCI telegram
36872 0x9008 Timeout error of msg wait function No reply could be received to a request
within the timeout.