EDS94AYCEN EN 9.0 - 09/2012 L 55
E94AYCEN communication manual (Ethernet)
Parameter reference
Parameters of the standard device that are relevant to communication
C00637
Parameter | Name:
C00637 | Resp. to new module in MXI2
Data type: UNSIGNED_32
Index: 23939
d
= 5D83
h
Response if a new module has been plugged into module slot 2 of the standard device.
Selection list (Lenze setting printed in bold)
1Fault
6 Information
5 Warning
4 Warning Locked
3 Quick stop by trouble
0 No Response
; Read access ; Write access CINH PLC STOP No transfer
Note!
The standard device codes C01501 and C01502 have no effect when using the
E94AYCEN (Ethernet) communication module.