5.2.5 Data Info
The table [Data Info] shows the measuring data determined for each cylin-
der in numerical order. All presentations and mathematical calculations of
the DPI software are based on these measurements.
Date, Time: Date and time of the measurement
Average cycles: number of measured cycles (number of averages)
Pmax_av: average peak pressure value of all measuring cycles
Pmax_max: highest peak pressure value of all measuring cycles
Pmax_low: lowest peak pressure value of all measuring cycles
MIP: mean indicated pressure
Deviation: standard deviation related to the mean value of all peak
pressures of a series of measurements.
Ptdc: pressure value at top dead center
RPM: engine speed
Max dp / da: 1. derivation of the pressure curve
Ind. Power: indicated cylinder power
Boost pressure: boost pressure of the engine
Ambient temp .: ambient temperature
The following values are not measured but can be optionally entered later
to complete the data record.
Exhaust gas temp .: exhaust gas temperature
Fuel rack setting: position of the injection linkage
VIT setting: variable injection time
Additional information: space for entering additional information