EasyManua.ls Logo

Leutert DPI - Data Info Table

Leutert DPI
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Digital Pressure Indicator DPI - Bedienungsanleitung
36 Friedrich Leutert GmbH & Co. KG
5.2.5 Data Info
The table [Data Info] shows the measuring data determined for each cylin-
der in numerical order. All presentations and mathematical calculations of
the DPI software are based on these measurements.
– Date, Time: Date and time of the measurement
– Average cycles: number of measured cycles (number of averages)
– Pmax_av: average peak pressure value of all measuring cycles
– Pmax_max: highest peak pressure value of all measuring cycles
– Pmax_low: lowest peak pressure value of all measuring cycles
– MIP: mean indicated pressure
– Deviation: standard deviation related to the mean value of all peak
pressures of a series of measurements.
– Ptdc: pressure value at top dead center
– RPM: engine speed
– Max dp / da: 1. derivation of the pressure curve
– Ind. Power: indicated cylinder power
– Boost pressure: boost pressure of the engine
– Ambient temp .: ambient temperature
The following values are not measured but can be optionally entered later
to complete the data record.
– Exhaust gas temp .: exhaust gas temperature
– Fuel rack setting: position of the injection linkage
– VIT setting: variable injection time
– Additional information: space for entering additional information