Leuze electronic Connector unit
Leuze electronic BPS 8 23
TNT 35/7-24V
5 Connector unit
5.1 Modular connector unit MA 8-01
Using the RS 485 interface in a BPS 8 system always requires a MA 8-01 connector unit.
The connector unit is not only used to connect to the supply voltage and the RS 485 inter-
face, it also permits a switching input and switching output to be connected via a standard
sensor connector, and connection to the BPS 8 system via ready-made cables.
5.1.1 General information
The modular connector unit is an indispensable accessory when connecting a BPS 8 to an
RS 485 interface. The RS 485 interface, the switching input and the switching output are all
connected to the MA 8-01. It also supplies voltage to the BPS 8.
MA 8-01
The MA 8-01 offers the following interfaces:
M12 connection for RS 485 interface HOST/RS485
M12 connection for voltage supply PWR IN
M12 connection for switching input and switching output SW IN/OUT
M12 connection for BPS 8 BPS
5.1.2 Specifications of the connector unit
Mechanical data
Protection class IP 67
1)
1) with M12 connectors/caps screwed into place
Weight 70g
Dimensions (W x H x D) 86 x 30 x 25mm
Housing plastic
Connection type M12 connectors
Environmental data
Operating temperature range 0°C +50°C
Storage temperature range -30°C +80°C
Air humidity max. 90% rel. humidity, non-condensing
Standards applied IEC 801
Electromagnetic compatibility EN 55022, EN 61000-4-2, -3, -4 and -6, EN 61326-1,
CISPR 22, class B, ITE
FCC Part 15, Class B, ITE

Table of Contents

Other manuals for Leuze BPS 8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Leuze BPS 8 and is the answer not in the manual?

Leuze BPS 8 Specifications

General IconGeneral
BrandLeuze
ModelBPS 8
CategoryValve Positioners
LanguageEnglish

Related product manuals