8.1.4.3 Overview of Commands and Parameters
Online commands can be used to send commands directly to the BPS 8 for control and
configuration.
For this, the BPS 8 has to be connected to a host or service computer via the serial interface.
The commands described can be sent either via the host or the service interface.
General "Online" commands
Command Description
M+ Activates the measurement.
M- Deactivate the measurement.
MMS
Controls the data output via the service interface.
A single measurement value is output (Single Shot Mode).
MMTyyyy
Controls the data output via the service interface.
Measurement values are output cyclically; time must be subsequently
specified:
yyyy = time specification in ms.
Example: MMT0500.
Measurement values are output via the service interface in a
time interval of 500ms.
MM-
Deactivates the function MMTyyyy
If the cyclical output via the service interface is no longer required, the
function must be deactivated using the command MM-.
PC20 Resets all parameters in the BPS 8 to Leuze default values.
V
Version query, or puts the device into service mode.
This requires a "V" to be transmitted during the initialisation phase of the
BPS 8.