Leuze electronic Device parameters and interfaces
Leuze electronic BPS 8 63
TNT 35/7-24V
Parameters
Notice!
The events of the switch-on function and switch-off function are both linked to one another
with a logical OR.
Parameter Description Value range Default Unit CR
Digital
I/O Mode
Defines whether the switching input
and output are activated via the
MA 8-01 or whether only the switching
input or only the switching output are
activated.
0: Not released
1: BPS 8 with MA 8-01
(switching input +
switching output)
2: Switching input
3: Switching output
1 ––
DC bias level /
Invert
The parameter defines the DC bias
level of the switching output.
0: LOW (0V)
1: HIGH (+Ub)
0 ––
Pulse dura-
tion in [ms]
The parameter defines the switch-on
time period for the switching output. If
the value is 0, the signal is static.
0 … 1300 400 ms –
Activation [EF]
The parameter defines the events
which set the switching output:
Each
0: Not active
1: Active
–
- Outside measurement range 0
Position
Logging
,
- Inside measurement range 0
Position
Logging
,
- Erroneous measurement 1
Position
Logging
- Successful measurement 0
Position
Logging
Deactivation
[AF]
The parameter specifies the events
which reset the switching output:
Each
0: Not active
1: Active
–
–
- Outside measurement range 0
Position
Logging
,
- Inside measurement range 0
Position
Logging
,
- Erroneous measurement 0
Position
Logging
- Successful measurement 1
Position
Logging
a
b
c
d
i
j
i
j
e
i
j
i
j