Binary protocol type 2 Leuze electronic
74 BPS 8 Leuze electronic
Priority of the bits
• Priority 1: Diagnostic data
• Priority 2: Marker info
• Priority 3: SLEEP
• Priority 3: Position values
Notice!
It is advisable to set only one control bit for each control byte as the BPS can only answer
one query at a time. If several control bits are set, the function with the highest priority is ex-
ecuted.
Notice!
A0 and A1 are the address bits. If several BPS 8's operate in one network, an address con-
figuration is required.
Bit S-Bit 0: If this bit is set to 1, the marker information is output.
Bit S-Bit 1: If this bit is set to 1, the diagnostic data is sent in response. Any error indicated
is reset. This may be recognised by the status LED changing from red to
green.
Bit SLEEP: This bit is used to activate the SLEEP mode.