EasyManua.ls Logo

LevelOne FCS-3071 - Page 50

LevelOne FCS-3071
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
49
is from 1 to 99 minutes.
Triggered Action (Multi-option)
The Administrator can specify alarm actions that will take when network failure is detected.
All options are listed as follows:
Enable Alarm Output
Select the item to enable alarm relay output.
Record Stream to SD Card
Select the item and the alarm-triggered recording will be saved into your Micro SD card.
Pre-trigger buffer recording function allows users to check what happened to cause the
trigger. The pre-trigger buffer time range is from 1 to 3 seconds. Select <Upload for __
sec> to set the recording duration after alarm is triggered. The setting range is from 1 to
99999 seconds. Select <Upload during the trigger active> to record the triggered video
until the trigger is off.
NOTE: Please make sure the local recording (with Micro SD/SDHC card) is
activated so that this function can be implemented. Refer to Recording for
further details.
Send Alarm Message by FTP/E-Mail
The Administrator can select whether to send an alarm message by FTP and/or E-Mail
when an alarm is triggered.
Save
Click on the <Save> button to save all the settings mentioned above.

Other manuals for LevelOne FCS-3071

Related product manuals