4-30 Service Manual
5025-2xx, 4xx
Fuser exit sensor removal
See “Fuser exit sensor on page 7-7 for the part number.
1. Open the front cover.
2. Remove the fuser assembly. See “Fuser assembly removal” on page 4-26.
3. Remove the screw (A) securing the fuser exit sensor.
4. Disconnect the cable (B) from the fuser exit sensor.
5. Remove the lower end of the sensor with a flat blade screwdriver, and gently pull the sensor from the
bracket.
6. Remove the sensor.