Repair information 4-55
5025-2xx, 4xx
Toner meter cycle (TMC) card removal
See “Toner meter cycle card assembly” on page 7-7 for the part number.
1. Remove the rear shield. See “Rear shield removal” on page 4-11.
2. Remove the right cover assembly. See “Right cover assembly removal” on page 4-10.
3. Remove the waste toner bottle. See “Waste toner bottle removal” on page 4-60.
4. Remove the imaging unit (IU). See “Imaging unit (IU) removal” on page 4-35.
5. Disconnect the TMC cable from JCTM1 connector (A), and push the toner meter cycle card cable through
the frame opening.
Note: Observe the routing for reinstallation.
6. Remove the two plastic screws (B), the two metal screws (C), and remove the card.