Repair information 4-33
5025-2xx, 4xx
Image transfer unit (ITU) removal
See “Image transfer unit (ITU) assembly” on page 7-5 for the part number.
1. Write down the number of the new ITU before installing it. You will need the 16-digit numeric value from the
barcode after the installation, and it is easier to see at this point.
2. Remove the right cover assembly. See “Right cover assembly removal” on page 4-10.
3. Remove the waste toner bottle. See “Waste toner bottle removal” on page 4-60.
4. Remove the imaging unit (IU). See “Imaging unit (IU) removal” on page 4-35.
5. Disconnect the two springs (A) from the side frames, leaving the right one attached to the ITU.
6. Rotate the left spring (B), and pivot the cam away from the ITU so the spring and the cam are held out of
the ITU path.