Diagnostic information 2-33
5025-2xx, 4xx
5
Check the following values at JFUSES1:
Are the values approximately correct?
Go to step 6. Replace the controller
board. See “Controller
board removal” on
page 4-19.
6
Replace the fuser. See “Fuser assembly
removal” on page 4-26.
Does the error clear?
Problem resolved. Replace the controller
board. See “Controller
board removal” on
page 4-19.
Step Questions / actions Yes No
JFUSES1
Pin Value
5 +3.3 V dc
6 Ground
8 Ground
10 +2.7 V dc
11 Ground