Repair information 4-169
5026
Feed with bushing roller removal
1. Remove the high-capacity input tray (HCIT) top plate assembly. See “Top plate assembly removal” on
page 4-177.
2. Remove the four screws (A) securing the pass thru sensor bracket to the top plate assembly.
Note: The bushing may come off when removing the pass thru sensor bracket.
3. Remove the screw (B) securing the 46T gear (C) to the top plate assembly.
4. Remove the 46T gear.
5. Snap loose the feed roller (D), and remove.
A
B D
C