3-16 Service Manual
4061-xx0
Sensor Test (high capacity output stacker)
1.
Select Sensor Test from OUTPUT BIN TESTS.
2. Select Output Bin x (x=number of the output option to be tested).
The following screen is displayed:
HC Bin x TP=OPpassThru=Open Full=Open NearFull=Open
TP—High-capacity top position sensor
passThruHigh-capacity pass thru sensor
FullHigh-capacity bin full sensor (lower part of dual sensor)
NearFull—High-capacity bin near full sensor (upper part of dual sensor)
3. Manually actuate each of the sensors of the high-capacity stacker, and the display by each sensor toggles
from Open to Closed.
4. Press Back () or Stop ( ) to exit the test.
Sensor Tests (5-bin mailbox)
1.
Select Sensor Tests from OUTPUT BIN TESTS.
2. Select Output Bin x (x=number of the output option to be tested).
The following screen is displayed:
Output Bin x
P1=OP P2=OP L=NL
passThru5-bin mailbox pass thru sensor shows Open or Closed
mailboxEmpty—5-bin mailbox empty sensor shows Normal for a normal level, NearFull for nearly
full, and Full for full.
3. Manually actuate each of the sensors of the 5-bin mailbox,. The pass thru sensor will indicate Open or
Closed and the empty sensor (mailboxEmpty) indicates Normal, NearFull, or Full.
4. Press Back () or Stop ( ) to exit the test.
Diverter Test
This test verifies the functioning of each of the 5-bin mailbox output media diverters. If more than one 5-bin
mailbox is installed, all installed diverters or tested.
To run the Diverter Test, select Diverter Test from the OUTPUT BIN TESTS. The test runs once and stops.