Converter Control MAG.DRIVE L2
54
GA 05.130/3.02 - 05/98
r (read) = value can only be read
r /w (read/write) = value can be read and written
4.6.2 Settings converter
Menu item Description Adjustable value / option Ac-
cess
min. max. stan- Unit
value value dard
Option Relay Relay with change -over Threshold bearing
contact; the operator can temperature reached °C r/w
select one of the functions Threshold motor
described current reached A
Threshold frequency
the thresholds are adjusted reached Hz
in the next three menu items No cooling water -
no purge gas -
TMS temperature o.k. -
Vent -
Threshold Threshold bearing temp. 0 100 60 °C r/w
for option relay
Threshold Threshold motor current 0 20 10 A r/w
for option relay
Threshold Threshold frequency 0 480 300 Hz r/w
for option relay
Analog Output Analog output 0...10V; Motor current;
the operator can select 20 A =10Vxscale factor V r/w
one of the functions Act. frequency ;
described 500 Hz = 10Vxscale factorV
Bearing temp.;
100 °C = 10Vxscale factor V
Actual PVW13;
100% = 10Vxscale factor V
Actual PVW24;
100% = 10Vxscale factor V
Actual PZ12;
100% = 10Vxscale factor V
Scale Factor Scale factor for the analog output 0 2 1 - r/w
Analog Input 2 Analog input 0...10V ; No function - r/w
optionally frequency setpoint
via analog input 2 Function frequency
(10V = max. frequency setpoint) setpoint -
Start Delay Waiting time between start
command and acceleration 0 1200 0 s r/w
Display Display language English - r/w
German -
Bus Adress Bus adress for the converter by
operation via 0 31 0 - r/w
serial interface RS232/485
Acoustic Alarm OFF - r/w
Intermittent = warning ON -
Continuous = failure
German
Vent
TMS ok
No Purge gas
No Cooling Water
Frequency
Set Converter
Enter
Motor Current
Option Relay
Bearing Temp.
Enter
Threshold
60 °C
Enter
Threshold
10.0 A
Enter
Threshold
300 Hz
Enter
Actual PZ12
Actual PVW24
Actual PVW13
Bearing Temp.
Actual Frequency
Analog Output
Motor Current
Enter
Scale factor
1.0 x
Enter
Freq. Setpoint
Analog Input 2
No Function
Enter
Start delay
0 s
Enter
Display
English
Enter
Bus address
0
Enter
Acoustic Alarm
Off
Enter