PROGRAMMING MODE - SETUP MODE
Entering set up
mode.
You will see LqC1
Button Display
Press the
90°C (194°F)
button.
Press the
75°C (167°F)
or the
60°C (140°F)
button until
appears in the display.
Press the
Start
button.
Press the
75°C (167°F)
or the
60°C (140°F)
button until
appears in the display.
Press the
Start
button. Display . Press
75°C
(167°F)
or
60°C (140°F)
button to select course.
: 90°C (194°F) course
: 75°C (167°F) course
: 60°C (140°F) course
: 30°C (86°F)
,
40°C (104°F) course
: Cold course
Press the
Start
button.
Press
75°C (167°F)(+)
or
60°C (140°F)(-)
button and then
select , ,
23,8 KHz
23,3 KHz (default)
23,0 KHz
One or the other
will display.
Press the
Start
button.
The machine sets up the value of water level, then
advances to the next process automatically.
1. Continue to set up the next mode.
2.
Stop the change of setup value and go back to ready mode.
• Coin type - Turn on/off toggle switch.
• Card type - Pull the service card.
All types - Push the 90°C (194°F) button twice.
22. How to change the water level
You can change the water level by selecting options.
1. indicate water level 23,8 [KHz] (cold course : 23,8 KHz)
2. indicate water lever 23,3 [KHz] (cold course : 23,5 KHz)
3. indicate water lever 23,0 [KHz] (cold course : 23,0 KHz)
NOTE
This function is only controlled in machine. (It is not applied in setup card.)