PROGRAMMING MODE - SETUP MODE
Entering set up
mode.
You will see LqC1
Button Display
Press the
90°C (194°F)
button.
Press the
75°C (167°F)
or the
60°C (140°F)
button until
appears in the display.
Press the
Start
button.
Press the
75°C (167°F)
or the
60°C (140°F)
button until
appears in the display.
Press the
Start
button. Display . Press
75°C
(167°F)
or
60°C (140°F)
button to select course.
: 90°C (194°F) course
: 75°C (167°F) course
: 60°C (140°F) course
: 30°C (86°F)
,
40°C (104°F) course
: Cold course
Press the
Start
button.
Display previous top spin speed.
Press
75°C (167°F)(+)
or
60°C (140°F)(-)
button to select
top spin speed.
Press the
Start
button.
The machine sets up the top spin speed, then advances
to the next process automatically.
1. Continue to set up the next mode.
2.
Stop the change of setup value and go back to ready mode.
• Coin type - Turn on/off toggle switch.
• Card type - Pull the service card.
• All types - Push the 90°C (194°F) button twice.
18. Top spin speed – final spin time depends on RPM
Top spin speed setup can be used to set the maximum spin RPM.
NOTE
• Top spin speed
0 : 1150 rpm
1 : 1000 rpm
2 : 900 rpm
3 : 800 rpm
4 : 700 rpm
5 : 600 rpm
6 : 500 rpm