59
PROGRAMMING MODE - SETUP MODE
Enter setup mode.
You will see LqC1
Button Display
Press the
90°C (194°F)
button.
Press the
75°C (167°F)
or the
60°C (140°F)
button until
appears in the display.
Press the
Start
button.
Press the
75°C (167°F)
or the
60°C (140°F)
button until
appears in the display.
Press the
Start
button.
Display default shut down time.
Press
75°C (167°F)
or the
60°C (140°F)
button to select
time between 0~10.
(0 : Permanent standby, 1~10 : Shut down after
selected time)
To restart after Permanent standby, redistribute load
and press Start button.
Press the
Start
button.
The machine sets up the shut down time, then
advances to the next process automatically.
1. Continue to set up the next mode.
2. Stop the change of setup value and go back to ready
mode.
• Coin type - Turn on/off toggle switch.
• Card type - Pull the service card.
All types - Push the 90°C (194°F) button twice.
26. How to set shut down time after UE
Unbalance Error (UE) occurs when washer cannot balance the load within the selected drop counts.
can be used to set the time for maintaining the UE status before shutting down the cycle.