1 - GENERAL FEATURES
1.4 HANDLING AND STORAGE INSTRUCTIONS
Never pick the yarn feeder up by its yarn spool body, by its top
panel or by its tensioning unit.
The yarn feeder is supplied in an appropriate polystyrene casing;
please store the casing for use during any future handling.
1.5 INPUT FEELER
The yarn feeder features an input
feeler that provides the following
function:
• "Machine stop" function:
this function stops both the feeder
and the machine if no yarn is
detected at feeder input (broken
yarn or empty yarn spool).
Caution: the machine will not stop if the feeder comes to a halt.
The machine stop signal is operative only if the signal lamps are ON.
input feeler
YES NO
• Permanent magnet synchronous motor.
• Motor data:
Maximum power: 35 W
• Equivalent continuous A-weighted sound pressure level at maximum
speed: >70 dB (A)
• Operation and storage conditions:
- Room temperature: from +10 to +40 °C
- Maximum humidity: 80%