35
7 - ATTIVO
7.2 OFFSET
Upon first installation of this device, you need to enable the tension sensor
to acquire the OFFSET function (mechanical error zero function).
Follow the procedure below:
- Remove the yarn from the tension feeder.
- Switch off the feeder.
- Press the release button and hold it pressed until the device light turns on.
- Switch on the feeder.
- Light will turn off and OFFSET is obtained.
Note: The OFFSET procedure may have to be repeated even after the
equipment has been inoperative for some time.