1.7.1 Wiring diagram of the right hand side of the control unit
Fig.7showsadiagramoftheconnectionterminalsfortheaerial,variouscontrolsandthevariouspowersupplies(indicatorlight,electrolock,
ashinglight,courtesylight,photocells,selectors,etc.)..Thesearetheverticalterminalspositionedontherighthandsideofthecontrolunitand
numbered from 1 to 19.
8
• motor 1 : terminal 35 polarity -; terminal 36 polarity +.
• motor 2 : terminal 33 polarity -; terminal 34 polarity +.
1.7.2 Wiring diagram of the lower part of the control unitI
The terminals on the lower right hand part of the control unit are reserved for the connections for the board’s electricity supply through the transfor-
mer, the AGECH battery charger and the power supply of the two operators.
ATTENTION: thedenitionofleaf1andleaf2isessentialforautomationoperation.Fittersmustpaycarefulattentiontothefollowing.
Connect the motors to the control unit so that the leaf closure order is observed.
• motor 1 (terminals 35 -36): should be associated to leaf 1, 24 Vdc motor power output.
• motor 2 (terminals 33 -34): should be associated to leaf 2, 24 Vdc motor power output.
Respect the polarity of the cable terminals on the operator RED cable +, BLUE cable -:
1. Leaf 1:isthersttoopenwhenthegateisclosed
andthesecondtomovewhenthegateisopen;it
nishesitsclosuretravelafterleaf2.
2. Leaf 2: is the second to open when the gate is
closedandthersttomovewhenthegateis
open;itnishesitsclosuretravelbeforeleaf1.
TerminalsDescription(seewiringdiagramonpage2A)
1 - 2 Aerial:aerialcableinput1sheath,2cables.UseaRG58-50ohmcable
6 Common: for stop, open, close, step and photo inputs.
6 - 7 STOP*: programmable NC input, commands gate stoppage. Can be connected to safety devices such as an emergency stop button.
When the command is released automatic closure never occurs and a new movement command must be given.
Leave jumpered if no device is envisaged
6 - 8 OPEN: NO input, commands gate opening.
6 - 9 CLOSE: NO input, commands gate closure.
6-10 STEP:NOinput,commandsgatemovementaccordingtothefollowingcycles:
SEMI-AUTOMATIC MODE: Open, stop, close, stop.
4-STEP MODE Open, pause, close, pause.
2-STEP MODE Open - close
CONDOMINIUM MODE: Open.
6 -11 PHOTO*: programmable NC input for photocells or safety devices. Does not intervene during gate opening, during closure causes
reversalofmotionuntilcompleteopening.Leavejumperedifnodeviceisenvisaged
12 - 16 INDICATOR LIGHT: 24Vdc3Wmaxoutput,forconnectinganindicatorlightthatcopiesthefunctionoftheashinglightduringmove
ment and that remains on when the gate is open.
13 - 16 ELECTROLOCK 12Vdcoutputforconnectinga24Vdc15VAelectrolock.ToactivateselecttheOPENINGRAMBLOWfunction.
Deactivated by default.
14 - 16 FLASHING LIGHT:24Vdc25WmaxoutputforconnectingaSplendorSPL24ashinglightcharacterisedbythreeashingmodes:
1)slowduringdooropening;2)fast(ashingtimeshalved)duringclosure.3)threeashesandapausetoindicateafaultstateortravel
identication.
15 - 16 COURTESY LIGHT:24Vdc15Wmax.outputforconnectingacourtesylightthatswitchesonatthestartofeachmovement(opening
orclosure)andischaracterisedbyanadjustableontime(seechap.7.4.4).
16 +
17 -
18 - 19 24 Vac OUTPUT(200mAmax):powersupplyforvariousdevices,e.g.photocells,externalradioreceivers.
N.C. = normally closed contact – NO = normally open contact
* 6-7 and 6-11 are NC inputs that can be set as photo, photo1, photo2, stop, pause.
Photo:NCinputforphotocellsorsafetydevices.Doesnotinterveneduringgateopening;duringclosurecausesreversalofgatemotionuntil
open.
Photo 1: NC input for photocells or safety devices. Causes gate stoppage during both opening and closure. Motion resumes during opening when
the photocell or safety device is disengaged.
Photo 2:NCinputforphotocellsorsafetydevices.Doesnotinterveneduringgateclosure;duringgateopeningitcausesabriefreversalofmo-
tion, followed by stoppage until a new command is given.
Stop: commands gate stoppage. When the command is released automatic closure never occurs and a new movement command must be given.
Pause: causes a pause in the doors motion. If automatic closure at the end of the pause time is active, it causes re-closure, otherwise it waits for
a new command.
Pedestrian:thecommandcausespartialandadjustableopeningofasingleleaf.Canbegivenusingaremotecontrolortheterminalboard.
Obtainedfromtheterminalboardbyjumperingterminal8OPENwithterminal9CLOSE,thisjumperthenconnectswithaswitchtoterminal6
COMMON. When given from the terminal board, the PEDESTRIAN command excludes the OPEN and CLOSE commands.
TerminalsDescription(seewiringdiagramonpage2A)
20-21 24Vac Transformerpowerinput.
22-23 16Vac
24 AGECHbatterychargerconnection(optional).
33 -
34 +
35 -
36 +
Motor2,24Vdcpowersupply
Motor1,24Vdcpowersupply
30 Vdc OUTPUT: power supply for various devices
2 MAN.ISTRUZ.GE UNI24R (GB).indd 8 30-10-2008 16:40:57