13
a) Leaf 2 closure stop plate identication:
Give the step command (A) holding it down until leaf (2) reaches and pushes for a few seconds against the closure stop plate. When the lea
(2)hasidentiedtheclosurestopplatetheredLED(DX) only remains lit.
b) Leaf 1 closure stop plate identication:
Give the step command (A) again, holding it down until leaf 1 reaches and pushes for a few seconds against the closure stop plate. If the
closurestopplateshavebeencorrectlyidentied,theredLEDsonlyremainlitonthecontrolunit.
A) SINGLE LEAF ‘ONE TOUCH’ PROGRAMMING
a) Press , the red LED on the right-hand side will remain lit.
b)Press;
c) Press the step command key (A) on the radio control: the automation will perform, in sequence, a closure, an opening, a closure.
d)Havingcompletedtheself-programming,withthegate(s)closedthetwogreenLEDsashandtheredoneremainslit.
The automation is now in semi-automatic mode by default.
Perform standard installation if you are dissatised with the result obtained.
B) SINGLE LEAF STANDARD PROGRAMMING
a) Press , the red LED on the right-hand side will remain lit.
b) Closure stop plate identication: Give the step command (A), holding it down until the leaf reaches and pushes for a few seconds against
theclosurestopplate.Whiletheleafcloses,thetworight-handredandgreenLEDsash,whentheleafreachesthestopplatetheredLED
only remains lit.
Iftheclosurestopplatehasbeencorrectlyidentied,theredLEDsonlyremainlitonthecontrolunit.
corsadiapertura.Seilnecorsadiaperturaèstatoappresocorrettamentesullacentralerimangonoaccesisoloiledrossi.
The automation is now programmed. The automation is now in semi-automatic mode by default.
Ifyouaredissatisedwiththeresultobtained,reset the control unit and repeat procedure from start.
N.B.
•Duringthemovementofleaf1thelateralLEDsontheleft-handsidewillashalternately.
•Duringthemovementofleaf2thelateralLEDsontheright-handsidewillashalternately.
c) Opening stop plate identication: Give the step command (A) and release, the leaf opens until it reaches and pushes for a few seconds
against the opening stop plate.
Iftheopeningstopplatehasbeencorrectlyidentied,theredLEDsonlyremainlitonthecontrolunit.
d) Give the step command (A) and release, the leaf closes until it reaches and pushes for a few seconds against the closure stop plate.
Whentheleafhasreachedtheclosurestopplate,checkthatthetwogreenLEDsareashingandthatthetworedLEDSarelit.
The automation is now programmed. The automation is now in semi-automatic mode by default.
Ifyouaredissatisedwiththeresultobtained,resetthecontrolunitandrepeatprocedurefromstart.
ATTENTION: to regulate the leaf force and speed refer to the FORCE FUNCTION and OBSTACLE DETECTION FUNCTION chapters. The
tter must compulsorily perform the measurement of the gate’s impact force. For this purpose refer to the EN 12445 standard which
species the equipment to be used to perform opening and closure force measurement and the points in which the forces must be
measured and the direction of measurement.
B) STANDARD PROGRAMMING
c) Identication of staggering and opening stop plate:
Give the step command (A) and release, the leaf (1) will open. When it reaches the point at which one also wishes to open leaf (2)(opening
staggering)givethestepcommand (A) and release: leaf (2) will open.
The two leafs will now continue to open until they reach and push against the opening stop plates for a few seconds. If the opening stop plates
havebeencorrectlyidentied,theredLEDsonlyremainlitonthecontrolunit.
d) Identication of closure staggering:
Give the step command (A) and release, the leaf (2) will close. When it reaches the point at which one also wishes to close leaf (1)(closure
staggering)givethestepcommand(A) and release: leaf (1) will close. The two leafs will now continue to close until they reach and push
against the opening stop plates for a few seconds.
e) When both leafs (1) and (2)havereachedtheclosurestopplate,checkthatthetwogreenLEDsareashingandthatthetworedLEDsarelit.
2.3.1.2 Single leaf gate
There are two initial programming modes available:
a) ‘ONE TOUCH’: automatic programming in which the various operations are performed automatically with default settings established by
LIFE.Thismodeisrecommendedforlightweightleafsandopeningsofupto90°.
b) STANDARD:theinitialmanoeuvresarecontrolledbythetter.
ENGLISH