19
To set DECELERATION IN OPENING press
followed by .
To set DECELERATION IN CLOSING press
followed by .
The various distances are set by pressing and .
The minimum deceleration value is 4% of total travel.
3.3.11 Deceleration in opening and closure.
Thisfunctionregulatesthedistancetravelledbythegateindecelerationinthenalstretchesofopeningandclosure.
Pressfollowedby;
ifgreenLED(SX)islit:scaleofvalueswithless
rapidresponse;
ifredLED(SX)islit:scaleofvalueswithmore
rapidresponse;
The various values are set by pressing and .
Press to change the response scales.
3.3.12 Obstacle detection
Theautomationisttedwithanobstacledetectionsystem:thegateinvertsitsmovementwhenitstrikesanobstacleduringtheopeningandclosure
phases. Sensitivity regulation consists in a greater or lesser rapidity in response to the obstacle.
1)Duringtheclosurephaseifthecontrolunitidentiesanobstacle,thegateinvertsmotionandperformscompleteopening.Iftheobstacleis
detected 3 times consecutively, the gate stops in a completely open position awaiting a command.
2)Ifthecontrolunitidentiesanobstacle,thegateperformsashortreversalofmotion,beforestoppingawaitingacommand.
3)Inthetwodecelerationphasesthegatestopsifanobstacleisdetected.
Press followed by .
The various values are set by pressing and .
3.3.13 Pedestrian opening
Pedestrian opening is characterised by the opening of leaf 1.
This function regulates the amplitude of partial leaf opening associated to the pedestrian command.