Chapter 6: Using the Web-based Utility
The Voice Tab
IP Telephony System
Prefer G726r32 Code. This is the dialing code that will make this codec the preferred codec for the associated
call. The default is *0172632.
Force G726r32 Code. This is the dialing code that will make this codec the only codec that can be used for the
associated call. The default is *0272632.
Prefer G726r40 Code. This is the dialing code that will make this codec the preferred codec for the associated
call. The default is *0172640.
Force G726r40 Code. This is the dialing code that will make this codec the only codec that can be used for the
associated call. The default is *0272640.
Prefer G729a Code. This is the dialing code that will make this codec the preferred codec for the associated call.
The default is *01729.
Force G729a Code. This is the dialing code that will make this codec the only codec that can be used for the
associated call. The default is *02729.
Miscellaneous
Set Local Date (mm/dd). Set the local date (mm stands for months and dd stands for days). The year is optional
and uses two or four digits.
Set Local Time (hh/mm). Set the local time (hh stands for hours and mm stands for minutes). Seconds are
optional.
Time Zone. For caller ID generation, select the number of hours to add to GMT to generate the local time. The
default is GMT-08:00.
FXS Port Impedance. This sets the electrical impedance of the FXS port. Select one of these choices: 600, 900,
600+2.16uF, 900+2.16uF, 270+750||150nF, 220+850||120nF, 220+820||115nF, or 370+620||310nF. The
default is 600.
Daylight Saving Time Rule. Enter the rule for calculating daylight saving time; it should include the start, end,
and save values. This rule is comprised of three fields. Each field is separated by ; (a semicolon) as shown below.
Optional values inside [ ] (the brackets) are assumed to be 0 if they are not specified. Midnight is represented by
0:0:0 of the given date.
This is the format of the rule: Start = <start-time>; end=<end-time>; save = <save-time>
The <start-time> and <end-time> values specify the start and end dates and times of daylight saving time. Each
value is in this format: <month> /<day> / <weekday>[/HH:[mm[:ss]]]
Figure 6-35: Voice - Regional Screen - Miscellaneous
VoIPon Solutions www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0) 1245 600560

Table of Contents

Other manuals for Linksys SPA9000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Linksys SPA9000 and is the answer not in the manual?

Linksys SPA9000 Specifications

Physical Interfaces IconPhysical Interfaces
Ethernet ports2 10/100BaseT RJ-45
Phone ports2 RJ-11 FXS
Ring voltage40-55 VRMS
Ring frequency10 Hz - 40 Hz
Maximum ringer load3 REN
Power IconPower
On-hook voltage-50 V NOMINAL
Off-hook current25 mA min
Terminating impedanceConfigurable, including 600 ohms