Rev: 11.11.21 Page 18 CCD-0004203
Hydraulic Landing - Level Bracket
Accepted HYD Landing Gear and Leveling Bracket Supports Engineering Guidelines - REV: (3/1/2021)
18.1 HYD landing gear brackets should mount between 1/2" & 2 1/4" from front of I-beam.
½"
2¼"
18.2 Two web stiffeners are required per bracket.
18.3 Stiffeners need to be either a 13ga 1x2 XMC that extends the height of the web, or a 1" wide ¼ ga.
strap that is 2" shorter then the height of the I-beam.
Note: Below are some accepted mounting orientations.
18.4 All jack brackets require supports regardless of I-beam height.
If GVWR is ≤ 15.5K then 1x2 13ga tube must be used.
18.5 All rear leveling brackets should mount with I-beam flange
in slot of leveling bracket, unless otherwise approved by Lippert
engineering.