Lite-On Technology Corp.
Industrial Automation
125
PB-37
VSG1
Gain for the vibration suppression of low
frequency (1)
Communication
address:
014AH
014BH
Initial value
0
Control mode
P
Unit
dB
Configuration range
0 ~ 32
Data size
16bit
Data format
Dec
This is the parameter for setting the gain of the first filter for vibration suppression of low frequency. The
greater the gain the better the vibration suppression. The excessive setting may result in uneven operation
of the motor. It is suggested to increase the setting gradually.
PB-38
VSF2
Frequency for the vibration suppression of low
frequency (2)
Communication
address:
014CH
014DH
Initial value
1000
Control mode
P
Unit
0.1Hz
Configuration range
10 ~ 10000
Data size
16bit
Data format
Dec
This is the parameter for setting the frequency of the second filter for vibration suppression of low
frequency. If PB-39 is set to 0, the second filter for vibration suppression of low frequency is turned off.
PB-39
VSG2
Frequency for the vibration suppression of low
frequency (2)
Communication
address:
014EH
014FH
Initial value
0
Control mode
P
Unit
dB
Configuration range
0 ~ 32
Data size
16bit
Data format
Dec

Table of Contents