LOADRITE SPRINT OPERATORS MANUAL
21
Press to confirm.
The Loadrite displays Long Tot
Cleared for a few seconds and
then returns to the Ready screen.
Note that the Short Total is also
cleared for consistency.
Ready
0
Auto Add On/Off Setting (Auto Add)
Auto Add is an optional feature that is selected during installation. If Auto-
Add is enabled, the Loadrite can automatically operate the ADD function
every time a load is lifted past the trigger point.
To turn on/off Auto Add function
1. Press .
2. Use to scroll to Auto Add.
3. Press to select.
4. Use to adjust the setting.
5. Press to accept the setting.
Rotary Trigger Position Screen (TrigScrn)
This function displays a bar graph that reflects the current position of the
rotary trigger. It is available only if the rotary trigger is installed.
>>>>---+
0
Bar graph
+ trigger point,
>>> current bucket
position from ground
--- distance away from
trigger point
To turn on/off Rotary Trigger Position Screen
1. Press .