9 Specifications
Suitable Applications
The Loadrite measures weight by sensing the hydraulic pressure required
to lift a load. A trigger mechanism senses the position of the lifting arms.
Typical vehicles using the Loadrite system are:
• Front end loaders (bucket and/or fork)
• Forklift trucks.
Minimal Weighing Delay
Weighing delay is minimal, because the weighing function is carried out
during a normal lift. Loader should be stationary.
Power requirements
Supply Voltage 12 to 32 Volts DC
Supply current Loadrite indicator: 160mA
typical, 350mA max.
Loadrite printer: 50mA standby,
4A peak.
Automatic transient suppression exceeds relevant SAE specifications
for DC automotive power supply transients.
Signal Inputs and Outputs
Pressure transducer input 1 - 20mA (0-100%).
Trigger input (Magnetic) Pull up resistor requiring switch
to ground
Serial communications. RS232C protocol to printer and
data logger
Display
LCD display Back light
Keypad
6 keys Back light. Special functions