Special functions
909.4119.9-02 - 35 -07.19
Fuse options
Parameter
value
Mains fuse max. current I
1
230 V TIG MMA
16* 16A 200A 180A
16F 16A 200A 180A
13 13A 190A 160A
13F 13A 190A 160A
10 10A 180A 125A
10F 10A 180A 125A
Parameter
value
Mains fuse max. current I
1
115 V TIG MMA
25* 25A 180A 140A
25F 25A 180A 140A
20 20A 170A 125A
20F 20A 170A 125A
Tab. 3: Fuse options
*
) master reset
The “F” label indicates a fuse character-
istic that reduces the welding current
earlier to prevent fast fuses from trip-
ping.
18 Special functions
Master Reset
Caution! All personal settings will be
lost.
All welding and secondary parameters
as well as the machine conguration
are reset to master reset values.
Press buttons 19 and 20 simultaneously for at
least 5 seconds.
The 7-segment display and the control panel
indicators light up briey for conrmation and
the system restarts.