Chapter 11 TR Output Option Board
11 - 3
11.3 Positioning Specification
Positioning function is built in XGB output option board. This describes specification, how-to-use, function,
programming and wiring of built-in positioning.
11.3.1 Performance Specification
(1) Performance Specification
Model
Item
XBO-TN04A
No. of axes
2
Control method
Position control, speed control
Control unit
Pulse
Positioning
Method
Incremental
Address range
-2,147,483,648 2,147,483,647(pulse)
Speed range
1 10,000pps(1pps unit)
Manual operation
JOG operation
Home return
By DOG
Max. connection
distance
2 m
Connector
6 Pin connector
11.3.2 Name of each part
(1) Name of each part
Item
XBO-TN04A
Diagram
Structure
Inner
circuit
www.behaotomasyon.com