Appendix 1 Flag List
App. 1 - 14
No. Keyword Type Contents Description
N00041 _P1B01SN Word
P2P parameter 1, 01
block another station no.
Saves another station no. of P2P parameter 1, 01
block.
In case of using another station no. at XG-PD, it is
possible to edit during RUN by using P2PSN
command.
N00042 ~
N00045
_P1B01RD1
Device
structure
Area device 1 to read
P2P parameter 1, 01
block
Saves area device 1 to read P2P parameter 1, 01
block.
N00046 _P1B01RS1 Word
Area size 1 to read P2P
parameter 1, 01 block
Saves area size 1 to read P2P parameter 1, 01 block.
N00047 ~
N00050
_P1B01RD2
Device
structure
Area device 2 to read
P2P parameter 1, 01
block
Saves area device 2 to read P2P parameter 1, 01
block.
N00051 _P1B01RS2 Word
Area size 2 to read P2P
parameter 1, 01 block
Saves area size 2 to read P2P parameter 1, 01 block.
N00052 ~
N00055
_P1B01RD3
Device
structure
Area device 3 to read
P2P parameter 1, 01
block
Saves area device 3 to read P2P parameter 1, 01
block.
N00056 _P1B01RS3 Word
Area size 3 to read P2P
parameter 1, 01 block
Saves area size 3 to read P2P parameter 1, 01 block.
N00057 ~
N00060
_P1B01RD4
Device
structure
Area device 4 to read
P2P parameter 1, 01
block
Saves area device 4 to read P2P parameter 1, 01
block.
N00061 _P1B01RS4 Word
Area size 4 to read P2P
parameter 1, 01 block
Saves area size 4 to read P2P parameter 1, 01 block.
N00062 ~
N00065
_P1B01WD
1
Device
structure
Area device 1 to save
P2P parameter 1, 01
block
Saves area device 1 to save P2P parameter 1, 01
block.
N00066 _P1B01WS1 Word
Area size 1 to save P2P
parameter 1, 01 block
Saves area size 1 to save P2P parameter 1, 01 block.
N00067 ~
N00070
_P1B01WD
2
Device
structure
Area device 2 to save
P2P parameter 1, 01
block
Saves area device 2 to save P2P parameter 1, 01
block.
N00071 _P1B01WS2 Word
Area size 2 to save P2P
parameter 1, 01 block
Saves area size 2 to save P2P parameter 1, 01 block.
N00072 ~
N00075
_P1B01WD
3
Device
structure
Area device 3 to save
P2P parameter 1, 01
block
Saves area device 3 to save P2P parameter 1, 01
block.
N00076 _P1B01WS3 Word
Area size 3 to save P2P
parameter 1, 01 block
Saves area size 3 to save P2P parameter 1, 01 block.
N00077 ~
N00080
_P1B01WD
4
Device
structure
Area device 4 to save
P2P parameter 1, 01
block
Saves area device 4 to save P2P parameter 1, 01
block.
N00081 _P1B01WS4 Word
Area size 4 to save P2P
parameter 1, 01 block
Saves area size 4 to save P2P parameter 1, 01 block.
Notes
N area shall be set automatically when setting P2P parameter by using XG-PD and available to modify during RUN
by using P2P dedicated command.
N area has a different address classified according to P2P parameter setting no., block index. The area not used
by P2P service as address is divided, can be used by internal device.